Siemens.mc.drives.acx.model.configuration Data.package Container |link| Guide

| Error Message | Root Cause | Solution | | :--- | :--- | :--- | | ACX inconsistency: Version mismatch | The container was created with TIA v17, but target project is v15. | Export container in legacy format or upgrade the project. | | Data package container: Missing topology | The container references a drive object (e.g., "Drive_3") that doesn't exist in the hardware configuration. | Use the "Reset topology from actual configuration" wizard. | | Model.configuration invalid: p0922 | The telegram (communication standard) defined in the container does not match the controller's configured telegram. | Check PROFIdrive interface in both PLC and drive. | | Container checksum error | The file was corrupted during transfer (e.g., USB drive removal while writing). | Re-export the container from the original source project. |

Engineers often encounter errors related to this data package. Here is how to interpret them: | Error Message | Root Cause | Solution

This path indicates a software object model used for handling configuration data for Siemens drives: | Use the "Reset topology from actual configuration" wizard